Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.736/1.736, allocations: 285.4 MB / 298 MB, free: 5.965 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001566/0.001567, allocations: 176.8 kB / 366.4 MB, free: 2.078 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.787/1.787, allocations: 205.1 MB / 0.6248 GB, free: 7.727 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008568/0.0008569, allocations: 97.98 kB / 0.738 GB, free: 40.27 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.444e-05/3.448e-05, allocations: 4 kB / 0.8583 GB, free: 13.08 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8406/0.8406, allocations: 115.3 MB / 0.9709 GB, free: 77.78 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.674/6.514, allocations: 2.446 GB / 3.417 GB, free: 3.762 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003098/6.515, allocations: 108.9 kB / 3.417 GB, free: 3.703 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Sensors/MassFractionTwoPort.mo:27:11-27:55:writable] Error: Variable Medium.substanceNames[1:Medium.nXi] not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Sensors/MassFractionTwoPort.mo:26:3-28:103:writable] Error: Class Medium.MassFraction not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra while instantiating masFra.XiVec. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop Notification: Performance of FrontEnd: time 1.314/7.829, allocations: 379.7 MB / 3.788 GB, free: 11.76 MB / 0.948 GB