Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|QAggShi_flow.3.|QAggShi_flow.4.",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells") translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|QAggShi_flow.3.|QAggShi_flow.4.",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.428/1.428, allocations: 249.3 MB / 261.8 MB, free: 5.914 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001069/0.001069, allocations: 182.5 kB / 321.3 MB, free: 14.65 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.382/1.382, allocations: 205.2 MB / 0.572 GB, free: 10.63 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007882/0.0007883, allocations: 99.2 kB / 0.6764 GB, free: 15.6 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 2.698e-05/2.7e-05, allocations: 4 kB / 0.788 GB, free: 97.06 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1823/0.1824, allocations: 106.3 MB / 0.8918 GB, free: 6.633 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6885/0.8709, allocations: 132.5 MB / 1.021 GB, free: 2.285 MB / 0.6355 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002853/0.8712, allocations: 106.2 kB / 1.021 GB, free: 2.219 MB / 0.6355 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/ShiftAggregationCells.mo:15:5-20:21:writable] Error: Type mismatch for named argument in Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.shiftAggregationCells(rCel={1, 1, 1, 2, 2}). The argument has type: Integer[5] expected type: Real[i] Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells Notification: Performance of FrontEnd: time 0.002051/0.8733, allocations: 0.8476 MB / 1.022 GB, free: 1.469 MB / 0.6355 GB