Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.252/2.252, allocations: 387.1 MB / 399.7 MB, free: 9.48 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001062/0.001062, allocations: 173 kB / 492.3 MB, free: 0.6055 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.722/1.722, allocations: 221.3 MB / 0.7871 GB, free: 12.9 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009207/0.0009207, allocations: 91.91 kB / 0.9267 GB, free: 13.98 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 3.474e-05/3.477e-05, allocations: 4 kB / 1.073 GB, free: 180.4 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3941/0.3941, allocations: 142.3 MB / 1.212 GB, free: 38.5 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.409/6.804, allocations: 1.958 GB / 3.171 GB, free: 369.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002838/6.804, allocations: 99.94 kB / 3.171 GB, free: 369.3 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 1.722/8.526, allocations: 429.7 MB / 3.59 GB, free: 304.4 MB / 1.151 GB