Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.638/1.638, allocations: 289.7 MB / 302.3 MB, free: 2.156 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001182/0.001182, allocations: 183.8 kB / 371.6 MB, free: 3.355 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.036/2.036, allocations: 205.1 MB / 0.6309 GB, free: 11.79 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001021/0.001021, allocations: 88.8 kB / 0.745 GB, free: 54.42 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 4.495e-05/4.498e-05, allocations: 4 kB / 0.8662 GB, free: 15.09 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3702/0.3703, allocations: 116.3 MB / 0.9798 GB, free: 10.62 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.257/7.628, allocations: 2.092 GB / 3.071 GB, free: 148.1 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002546/7.628, allocations: 89.64 kB / 3.071 GB, free: 148 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice Notification: Performance of FrontEnd: time 1.128/8.756, allocations: 167.6 MB / 3.235 GB, free: 219.5 MB / 0.948 GB