Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.725/1.725, allocations: 289.7 MB / 302.3 MB, free: 2.156 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001183/0.001183, allocations: 183.1 kB / 371.6 MB, free: 3.379 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.909/1.909, allocations: 205.1 MB / 0.6309 GB, free: 11.77 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001163/0.001164, allocations: 90.42 kB / 0.745 GB, free: 54.57 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 4.188e-05/4.191e-05, allocations: 4 kB / 0.8662 GB, free: 15.06 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3277/0.3278, allocations: 116.3 MB / 0.9798 GB, free: 10.6 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.014/7.342, allocations: 2.133 GB / 3.113 GB, free: 104.2 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002995/7.342, allocations: 101.8 kB / 3.113 GB, free: 104.1 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter Notification: Performance of FrontEnd: time 8.063/15.41, allocations: 1.631 GB / 4.744 GB, free: 97.22 MB / 0.9948 GB