Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.588/1.588, allocations: 289.7 MB / 302.2 MB, free: 2.117 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001059/0.001059, allocations: 178.5 kB / 371.6 MB, free: 3.402 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.388/1.388, allocations: 205.2 MB / 0.6309 GB, free: 11.76 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008481/0.0008482, allocations: 89.61 kB / 0.745 GB, free: 54.6 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 3.806e-05/3.809e-05, allocations: 7.984 kB / 0.8662 GB, free: 15.06 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2031/0.2031, allocations: 116.3 MB / 0.9798 GB, free: 10.6 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.316/1.52, allocations: 460.1 MB / 1.429 GB, free: 291.5 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000241/1.52, allocations: 96.56 kB / 1.429 GB, free: 291.5 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Boilers/Examples/BoilerPolynomialClosedLoop.mo:11:3-21:72:writable] Error: component boi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop Notification: Performance of FrontEnd: time 0.4375/1.957, allocations: 230.8 MB / 1.655 GB, free: 109.2 MB / 0.948 GB