Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Summer.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Summer,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Summer") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Summer,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Summer") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.5/2.5, allocations: 284.8 MB / 297.3 MB, free: 6.293 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001385/0.001384, allocations: 172.9 kB / 365.7 MB, free: 2.609 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.998/1.998, allocations: 205.1 MB / 0.6241 GB, free: 8.191 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001459/0.001459, allocations: 97.45 kB / 0.7372 GB, free: 40.77 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.537e-05/3.555e-05, allocations: 4 kB / 0.8574 GB, free: 13.71 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8034/0.8034, allocations: 115.2 MB / 0.97 GB, free: 78.28 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.171/8.975, allocations: 2.657 GB / 3.627 GB, free: 127.1 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003108/8.975, allocations: 100.8 kB / 3.627 GB, free: 127.1 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Guideline36Summer Notification: Performance of FrontEnd: time 12.42/21.4, allocations: 2.2 GB / 5.827 GB, free: 64.82 MB / 1.042 GB