Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.445/2.445, allocations: 284.8 MB / 297.3 MB, free: 6.344 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001498/0.001498, allocations: 179.8 kB / 365.7 MB, free: 2.574 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.941/1.941, allocations: 205.1 MB / 0.6241 GB, free: 8.18 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001159/0.001158, allocations: 100.1 kB / 0.7372 GB, free: 40.75 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.82e-05/3.827e-05, allocations: 8 kB / 0.8575 GB, free: 13.67 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8675/0.8675, allocations: 115.2 MB / 0.97 GB, free: 78.34 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.528/2.396, allocations: 0.5096 GB / 1.48 GB, free: 36.04 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003753/2.396, allocations: 110.3 kB / 1.48 GB, free: 35.98 MB / 0.8542 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/IntegratedPrimaryLoadSide.mo:47:3-49:73:writable] Notification: From here: [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/BaseClasses/PartialPlant.mo:65:3-67:73:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: Modelica.Blocks.Sources.BooleanStep onChi(startTime(displayUnit = "h") = 7200) "On and off signal for the chiller" second element is: .Modelica.Blocks.Sources.BooleanStep onChi(startTime = 7200) "On and off signal for the chiller" Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide Notification: Performance of FrontEnd: time 0.1813/2.578, allocations: 55.88 MB / 1.534 GB, free: 7.965 MB / 0.8698 GB