Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.146/2.146, allocations: 252.6 MB / 265.2 MB, free: 5.73 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001521/0.00152, allocations: 179.8 kB / 324.5 MB, free: 14.35 MB / 266.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.028/2.028, allocations: 205.4 MB / 0.5753 GB, free: 10.48 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001137/0.001137, allocations: 102 kB / 0.6797 GB, free: 15.69 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 3.6e-05/3.616e-05, allocations: 4 kB / 0.7911 GB, free: 96.59 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2602/0.2602, allocations: 106.2 MB / 0.8949 GB, free: 6.262 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.99/8.25, allocations: 2.336 GB / 3.231 GB, free: 214.8 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004267/8.251, allocations: 94.83 kB / 3.231 GB, free: 214.8 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir Notification: Performance of FrontEnd: time 1.109/9.359, allocations: 285.7 MB / 3.51 GB, free: 43.32 MB / 0.8698 GB