Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case960.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case960,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case960") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.151/2.151, allocations: 252.6 MB / 265.2 MB, free: 5.723 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001493/0.001493, allocations: 191.7 kB / 324.5 MB, free: 14.35 MB / 266.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.969/1.969, allocations: 205.4 MB / 0.5754 GB, free: 10.46 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001167/0.001167, allocations: 93.88 kB / 0.6797 GB, free: 15.7 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 3.915e-05/3.934e-05, allocations: 8 kB / 0.7911 GB, free: 96.59 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2164/0.2164, allocations: 106.2 MB / 0.8949 GB, free: 6.254 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.01/8.226, allocations: 2.373 GB / 3.268 GB, free: 222.4 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005061/8.227, allocations: 108.1 kB / 3.268 GB, free: 222.4 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case960 Notification: Performance of FrontEnd: time 0.8068/9.034, allocations: 231.5 MB / 3.494 GB, free: 58.16 MB / 0.8698 GB