Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.316/2.316, allocations: 252.6 MB / 265.2 MB, free: 5.68 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001472/0.001472, allocations: 183.8 kB / 324.5 MB, free: 14.4 MB / 266.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.008/2.008, allocations: 205.4 MB / 0.5753 GB, free: 10.48 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001159/0.001159, allocations: 98 kB / 0.6797 GB, free: 15.7 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 4.361e-05/4.371e-05, allocations: 4 kB / 0.7911 GB, free: 96.59 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2655/0.2656, allocations: 106.2 MB / 0.8949 GB, free: 6.258 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.063/8.328, allocations: 2.366 GB / 3.261 GB, free: 221 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004995/8.329, allocations: 105.2 kB / 3.261 GB, free: 221 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900 Notification: Performance of FrontEnd: time 0.762/9.091, allocations: 223.1 MB / 3.479 GB, free: 74.18 MB / 0.8698 GB