Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.129/2.129, allocations: 252.6 MB / 265.2 MB, free: 5.688 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001479/0.001479, allocations: 175.9 kB / 324.5 MB, free: 14.34 MB / 266.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.96/1.96, allocations: 205.4 MB / 0.5754 GB, free: 10.45 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001144/0.001144, allocations: 97.44 kB / 0.6797 GB, free: 15.69 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 3.393e-05/3.418e-05, allocations: 8 kB / 0.7911 GB, free: 96.57 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2046/0.2046, allocations: 106.2 MB / 0.8949 GB, free: 6.254 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.496/7.7, allocations: 2.332 GB / 3.227 GB, free: 1.266 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003252/7.701, allocations: 95.95 kB / 3.227 GB, free: 1.172 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection Notification: Performance of FrontEnd: time 1.513/9.214, allocations: 268.4 MB / 3.49 GB, free: 83.25 MB / 0.8698 GB