Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.163/2.163, allocations: 252.6 MB / 265.2 MB, free: 5.66 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001452/0.001451, allocations: 190.6 kB / 324.5 MB, free: 14.32 MB / 266.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.041/2.041, allocations: 205.4 MB / 0.5754 GB, free: 10.43 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001119/0.001119, allocations: 94.31 kB / 0.6797 GB, free: 15.68 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 3.679e-05/3.703e-05, allocations: 11.98 kB / 0.7911 GB, free: 96.57 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2119/0.2119, allocations: 106.2 MB / 0.8949 GB, free: 6.227 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.962/2.174, allocations: 0.494 GB / 1.389 GB, free: 202.8 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003496/2.174, allocations: 103.6 kB / 1.389 GB, free: 202.8 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:212:5-212:61:writable] Warning: Unused input variable nrow in function .Modelica.Utilities.Streams.readRealMatrix. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:213:5-213:64:writable] Warning: Unused input variable ncol in function .Modelica.Utilities.Streams.readRealMatrix. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Geothermal/Borefields/Validation/ConstantHeatInjection_100Boreholes.mo:51:3-63:73:writable] Error: component hea contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes Notification: Performance of FrontEnd: time 24.72/26.9, allocations: 4.267 GB / 5.656 GB, free: 61.8 MB / 0.9794 GB