Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.317/2.317, allocations: 252.6 MB / 265.2 MB, free: 5.695 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001487/0.001486, allocations: 189.4 kB / 324.5 MB, free: 14.41 MB / 266.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.065/2.065, allocations: 205.4 MB / 0.5754 GB, free: 10.48 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001144/0.001144, allocations: 100.6 kB / 0.6797 GB, free: 15.71 MB / 0.5261 GB Notification: Performance of FrontEnd - loaded program: time 4.588e-05/4.602e-05, allocations: 7.984 kB / 0.7911 GB, free: 96.61 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2141/0.2142, allocations: 106.2 MB / 0.8949 GB, free: 6.285 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.062/2.276, allocations: 417.1 MB / 1.302 GB, free: 240.4 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002753/2.276, allocations: 92 kB / 1.302 GB, free: 240.4 MB / 0.8542 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/CarnotVerifyCOP.mo:42:3-59:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP Notification: Performance of FrontEnd: time 0.4492/2.726, allocations: 148.9 MB / 1.448 GB, free: 121.4 MB / 0.8542 GB