Regular simulation: ./Buildings_7.0.0_Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.Plant_T_ClosedLoop -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0144576s reading init.xml | | | | | | 0.00166289s reading info.xml | | | | | | 0.000134522s [ 0.2%] pre-initialization | | | | | | 0.000227747s [ 0.4%] initialization | | | | | | 3.694e-05s [ 0.1%] steps | | | | | | 0.00306098s [ 5.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0021524s [ 3.6%] event-handling | | | | | | 0.0190684s [ 31.9%] overhead | | | | | | 0.0350644s [ 58.7%] simulation | | | | | | 0.0597454s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1056 steps taken | | | | | | 1426 calls of functionODE | | | | | | 272 evaluations of jacobian | | | | | | 73 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00114871s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.