Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow") Notification: Performance of loadModel(Buildings): time 3.891/3.891, allocations: 432.7 MB / 445.3 MB, free: 15.64 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 3.053e-05/3.074e-05, allocations: 4.969 kB / 0.5383 GB, free: 10.29 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1785/0.1785, allocations: 98.71 MB / 0.6347 GB, free: 1.879 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.271/6.449, allocations: 2.327 GB / 2.962 GB, free: 193.8 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003193/6.449, allocations: 104.4 kB / 2.962 GB, free: 193.8 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow Notification: Performance of FrontEnd: time 0.9164/7.366, allocations: 241.4 MB / 3.197 GB, free: 62.89 MB / 0.823 GB