Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Examples.HydronicHeating.TwoRoomsWithStorage.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Examples.HydronicHeating.TwoRoomsWithStorage,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Examples.HydronicHeating.TwoRoomsWithStorage") Notification: Performance of loadModel(Buildings): time 3.763/3.763, allocations: 432.7 MB / 445.3 MB, free: 15.65 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 2.896e-05/2.907e-05, allocations: 3.203 kB / 0.5383 GB, free: 10.32 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1736/0.1737, allocations: 98.73 MB / 0.6347 GB, free: 1.93 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.08/7.254, allocations: 2.697 GB / 3.331 GB, free: 186.8 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002431/7.254, allocations: 88.92 kB / 3.331 GB, free: 186.8 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Examples.HydronicHeating.TwoRoomsWithStorage Notification: Performance of FrontEnd: time 0.485/7.739, allocations: 142 MB / 3.47 GB, free: 137.2 MB / 0.8386 GB