Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel") Notification: Performance of loadModel(Buildings): time 3.755/3.755, allocations: 432.7 MB / 445.3 MB, free: 15.75 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 2.954e-05/2.964e-05, allocations: 2.938 kB / 0.5383 GB, free: 10.24 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1705/0.1706, allocations: 98.72 MB / 0.6347 GB, free: 1.898 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.029/1.199, allocations: 432.4 MB / 1.057 GB, free: 11.33 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003129/1.2, allocations: 104.7 kB / 1.057 GB, free: 11.27 MB / 0.8073 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:104:11-104:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Notification: Performance of FrontEnd: time 1.415/2.615, allocations: 343.3 MB / 1.392 GB, free: 25.9 MB / 0.823 GB