Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_5.0.1_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF") Notification: Performance of loadModel(Buildings): time 3.589/3.589, allocations: 403.3 MB / 415.4 MB, free: 12.98 MB / 330.7 MB Notification: Performance of FrontEnd - loaded program: time 3.517e-05/3.537e-05, allocations: 7.938 kB / 0.499 GB, free: 13.45 MB / 426.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4822/0.4823, allocations: 92.69 MB / 0.5895 GB, free: 14.47 MB / 490.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 5.82/6.302, allocations: 2.331 GB / 2.92 GB, free: 261.1 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004269/6.302, allocations: 110.2 kB / 2.92 GB, free: 261.1 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableTimeTmax. Error: Dimensions must be parameter or constant expression (in size(glass, 1)). [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/HeatTransfer/Data/GlazingSystems.mo:38:5-42:31:writable] Error: Dimensions must be parameter or constant expression (in size(glass, 1)). [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:96:7-96:25:writable] Error: Component roo.datConExtWin[1].glaSys of variability PARAM has binding window600 of higher variability VAR. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF Notification: Performance of FrontEnd: time 1.695/7.997, allocations: 343.5 MB / 3.256 GB, free: 158.4 MB / 0.7761 GB