Running command: translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=280,variableFilter="",fileNamePrefix="Buildings_5.0.1_Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer") Notification: Performance of loadModel(Buildings): time 3.486/3.486, allocations: 403.3 MB / 415.4 MB, free: 12.9 MB / 330.7 MB Notification: Performance of FrontEnd - loaded program: time 3.423e-05/3.436e-05, allocations: 7.938 kB / 0.499 GB, free: 13.36 MB / 426.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.483/0.4831, allocations: 92.67 MB / 0.5895 GB, free: 14.48 MB / 490.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 6.653/7.136, allocations: 2.659 GB / 3.249 GB, free: 159.3 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000262/7.136, allocations: 107 kB / 3.249 GB, free: 159.3 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableValueNoDer. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableValueNoDer. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-5:45:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Air/Systems/SingleZone/VAV/ChillerDXHeatingEconomizer.mo:111:3-122:69:writable] Error: component hvac.heaCoi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Air.Systems.SingleZone.VAV.Examples.ChillerDXHeatingEconomizer Notification: Performance of FrontEnd: time 7.226/14.36, allocations: 1.519 GB / 4.768 GB, free: 68.26 MB / 0.8386 GB