Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb") translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo): time 0.7266/0.7266, allocations: 132.3 MB / 144.9 MB, free: 10.7 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001244/0.001244, allocations: 169.2 kB / 176.9 MB, free: 2.176 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.461/1.461, allocations: 170.5 MB / 379.3 MB, free: 11.98 MB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001486/0.001486, allocations: 112.1 kB / 450 MB, free: 5.867 MB / 346.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.4903/0.4904, allocations: 73.39 MB / 0.6736 GB, free: 47.96 MB / 458.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 5.882/6.373, allocations: 2.436 GB / 3.109 GB, free: 126.8 MB / 0.6198 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002729/6.373, allocations: 100.5 kB / 3.109 GB, free: 126.8 MB / 0.6198 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-5:45:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/HeatExchangers/CoolingTowers/Examples/BaseClasses/PartialStaticTwoPortCoolingTower.mo:11:3-20:71:writable] Error: component tow contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.FixedApproachWetBulb Notification: Performance of FrontEnd: time 0.8163/7.189, allocations: 277.2 MB / 3.38 GB, free: 94.71 MB / 0.6198 GB