Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTUPControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 1.6 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTUPControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTUPControl") translateModel(Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTUPControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTUPControl") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo): time 0.5658/0.5658, allocations: 94.69 MB / 107.3 MB, free: 5.18 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001317/0.001317, allocations: 170 kB / 130.7 MB, free: 7.543 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.629/1.629, allocations: 170.5 MB / 324.5 MB, free: 4 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001756/0.001755, allocations: 116.5 kB / 386.6 MB, free: 16.3 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 4.648e-05/4.651e-05, allocations: 7.984 kB / 456 MB, free: 11.75 MB / 346.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5244/0.5245, allocations: 61.51 MB / 0.5054 GB, free: 49.66 MB / 394.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.895/2.419, allocations: 0.7453 GB / 1.251 GB, free: 56 MB / 0.5261 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002612/2.42, allocations: 88.48 kB / 1.251 GB, free: 55.91 MB / 0.5261 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/Fluid/HeatExchangers/BaseClasses/ntu_epsilonZ.mo:59:5-59:81:writable] Error: Cannot resolve type of expression 0 < flowRegime. The operands have types Integer, enumeration(ParallelFlow, CounterFlow, CrossFlowUnmixed, CrossFlowCMinMixedCMaxUnmixed, CrossFlowCMinUnmixedCMaxMixed) in component . Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTUPControl Notification: Performance of FrontEnd: time 2.06/4.48, allocations: 0.4931 GB / 1.744 GB, free: 61.45 MB / 0.5261 GB