Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_1.6_Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 1.6 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo) Running command: translateModel(Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable") translateModel(Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo): time 0.521/0.521, allocations: 94.69 MB / 107.3 MB, free: 5.184 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001149/0.001149, allocations: 173.4 kB / 130.7 MB, free: 7.539 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.45/1.45, allocations: 170.5 MB / 324.5 MB, free: 3.98 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001662/0.001662, allocations: 120.3 kB / 386.6 MB, free: 16.26 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 4.326e-05/4.328e-05, allocations: 4 kB / 456 MB, free: 11.74 MB / 346.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5184/0.5184, allocations: 61.51 MB / 0.5054 GB, free: 49.6 MB / 394.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.334/1.853, allocations: 418 MB / 0.9136 GB, free: 139.3 MB / 0.5261 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003108/1.853, allocations: 93.06 kB / 0.9137 GB, free: 139.3 MB / 0.5261 GB Error: Dimensions must be parameter or constant expression (in size(y, 1)). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/Fluid/Actuators/Valves/Examples/TwoWayValveTable.mo:32:5-32:31:writable] Error: Component valTab.flowCharacteristics of variability PARAM has binding datVal of higher variability VAR. Error: Error occurred while flattening model Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable Notification: Performance of FrontEnd: time 0.1728/2.026, allocations: 88.01 MB / 0.9996 GB, free: 97.27 MB / 0.5261 GB