Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Running command: translateModel(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature") translateModel(BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.8682/0.8682, allocations: 141.7 MB / 154.3 MB, free: 15.49 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001021/0.001021, allocations: 170.6 kB / 187.2 MB, free: 11.9 MB / 154.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.392/1.392, allocations: 221.3 MB / 441.4 MB, free: 4.66 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009013/0.0009012, allocations: 98.97 kB / 0.5124 GB, free: 24.12 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.001717/0.001717, allocations: 274.5 kB / 0.5939 GB, free: 7.996 MB / 442.7 MB Notification: Performance of FrontEnd - loaded program: time 3.243e-05/3.265e-05, allocations: 4 kB / 0.6834 GB, free: 12.29 MB / 0.5261 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4238/0.4238, allocations: 82.76 MB / 0.7643 GB, free: 108.7 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.7846/1.208, allocations: 394.4 MB / 1.149 GB, free: 12.84 MB / 0.6823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002714/1.209, allocations: 93.7 kB / 1.15 GB, free: 12.8 MB / 0.6823 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope BuildingSystems.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildingSystems.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature Notification: Performance of FrontEnd: time 0.5844/1.793, allocations: 86.51 MB / 1.234 GB, free: 234.6 MB / 0.698 GB