Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.775/0.775, allocations: 127.3 MB / 139.8 MB, free: 15.43 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00109/0.00109, allocations: 176.8 kB / 169.7 MB, free: 1.73 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.756/1.756, allocations: 205.1 MB / 404.5 MB, free: 1.59 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007949/0.0007947, allocations: 82.3 kB / 481.8 MB, free: 4.238 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 3.405e-05/3.416e-05, allocations: 8 kB / 0.5532 GB, free: 54.85 MB / 394.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1657/0.1658, allocations: 76.75 MB / 0.6281 GB, free: 10.04 MB / 426.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo:2:1-8495:13:writable] Error: Class Units.SI.Volume not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/DHW/Electric/ResistiveWaterHeater.mo:4:3-5:38:writable] Error: Class Modelica.Units.SI.Volume not found in scope BuildSysPro.Systems.DHW.Electric.ResistiveWaterHeater. Error: Error occurred while flattening model BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater Notification: Performance of FrontEnd: time 0.6071/0.7729, allocations: 100.6 MB / 0.7264 GB, free: 12.21 MB / 490.7 MB