Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.IBPSA.Fluid.Chillers.Validation.Carnot_TEva_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.IBPSA.Fluid.Chillers.Validation.Carnot_TEva_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.Chillers.Validation.Carnot_TEva_etaPL") translateModel(BuildSysPro.IBPSA.Fluid.Chillers.Validation.Carnot_TEva_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.Chillers.Validation.Carnot_TEva_etaPL") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.84/0.84, allocations: 127.3 MB / 139.8 MB, free: 15.45 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001273/0.001272, allocations: 183.9 kB / 169.7 MB, free: 1.73 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.954/1.954, allocations: 205.1 MB / 404.5 MB, free: 1.582 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009119/0.0009119, allocations: 73.67 kB / 481.8 MB, free: 4.242 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 3.234e-05/3.234e-05, allocations: 4 kB / 0.5532 GB, free: 54.81 MB / 394.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1828/0.1828, allocations: 76.75 MB / 0.6281 GB, free: 10 MB / 426.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.274/1.456, allocations: 385.1 MB / 1.004 GB, free: 129.8 MB / 0.6355 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002443/1.457, allocations: 95.19 kB / 1.004 GB, free: 129.8 MB / 0.6355 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope BuildSysPro.IBPSA.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model BuildSysPro.IBPSA.Fluid.Chillers.Validation.Carnot_TEva_etaPL Notification: Performance of FrontEnd: time 0.146/1.603, allocations: 85.55 MB / 1.088 GB, free: 48.34 MB / 0.6355 GB