Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr AixLib_AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package AixLib with version 1.3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/package.mo) Running command: translateModel(AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="AixLib_AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase600FF") translateModel(AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="AixLib_AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase600FF") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/package.mo): time 1.591/1.591, allocations: 264.5 MB / 277.1 MB, free: 4.336 MB / 218.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001091/0.001091, allocations: 184.8 kB / 334.6 MB, free: 11.47 MB / 282.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.228/1.228, allocations: 221.3 MB / 0.5989 GB, free: 10.11 MB / 458.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0007646/0.0007647, allocations: 94.17 kB / 0.7042 GB, free: 51.34 MB / 0.5418 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo): time 0.04968/0.04968, allocations: 11.88 MB / 0.821 GB, free: 480 kB / 0.573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo:9:42-9:258:writable] Notification: This is an open source dummy package of a commercial library. If you want it to be supported, you will need to add an implemention on our github repository: https://github.com/Modelica-OpenVendorSpecificLibraries. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0002918/0.0002919, allocations: 11.98 kB / 0.9292 GB, free: 1.625 MB / 0.6824 GB Warning: Requested package SDF of version 0.4.2, but this package was already loaded with version 0.0.0. You might experience problems if these versions are incompatible. Notification: Performance of FrontEnd - loaded program: time 3.914e-05/3.915e-05, allocations: 4 kB / 1.046 GB, free: 251 MB / 0.7293 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.162/0.162, allocations: 110.2 MB / 1.154 GB, free: 141 MB / 0.7293 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.117/5.28, allocations: 2.316 GB / 3.47 GB, free: 262.1 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003168/5.28, allocations: 103.2 kB / 3.47 GB, free: 262.1 MB / 0.948 GB Notification: Performance of FrontEnd - DAE generated: time 0.7433/6.023, allocations: 362.4 MB / 3.824 GB, free: 6.559 MB / 0.948 GB Notification: Performance of FrontEnd: time 2.525e-06/6.023, allocations: 0 / 3.824 GB, free: 6.559 MB / 0.948 GB Notification: Performance of Transformations before backend: time 0.0005281/6.024, allocations: 119.9 kB / 3.824 GB, free: 6.441 MB / 0.948 GB Error: Too many equations, over-determined system. The model has 1395 equation(s) and 1259 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1065 (size: 1) HDifTil[1].weaBus.HDifHor = HDirTil[3].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1064 (size: 1): HDifTil[1].weaBus.HDifHor = HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1066 (size: 1) HDifTil[1].weaBus.HDifHor = HDirTil[4].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1064 (size: 1): HDifTil[1].weaBus.HDifHor = HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1067 (size: 1) HDifTil[1].weaBus.HDifHor = HDirTil[5].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1064 (size: 1): HDifTil[1].weaBus.HDifHor = HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1087 (size: 1) HDifTil[1].weaBus.HGloHor = HDirTil[3].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1086 (size: 1): HDifTil[1].weaBus.HGloHor = HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1088 (size: 1) HDifTil[1].weaBus.HGloHor = HDirTil[4].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1086 (size: 1): HDifTil[1].weaBus.HGloHor = HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1089 (size: 1) HDifTil[1].weaBus.HGloHor = HDirTil[5].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1086 (size: 1): HDifTil[1].weaBus.HGloHor = HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1093 (size: 1) HDifTil[1].weaBus.HHorIR = HDifTil[3].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1094 (size: 1) HDifTil[1].weaBus.HHorIR = HDifTil[4].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1095 (size: 1) HDifTil[1].weaBus.HHorIR = HDifTil[5].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1097 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[2].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1098 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[3].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1099 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[4].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1100 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[5].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1092 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1104 (size: 1) HDifTil[1].weaBus.TBlaSky = HDifTil[3].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1105 (size: 1) HDifTil[1].weaBus.TBlaSky = HDifTil[4].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1106 (size: 1) HDifTil[1].weaBus.TBlaSky = HDifTil[5].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1108 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[2].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1109 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[3].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1110 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[4].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1111 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[5].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1103 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1116 (size: 1) HDifTil[1].weaBus.TDewPoi = HDifTil[3].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1117 (size: 1) HDifTil[1].weaBus.TDewPoi = HDifTil[4].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1118 (size: 1) HDifTil[1].weaBus.TDewPoi = HDifTil[5].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1120 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[2].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1121 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[3].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1122 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[4].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1123 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[5].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1115 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1127 (size: 1) HDifTil[1].weaBus.TDryBul = HDifTil[3].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1128 (size: 1) HDifTil[1].weaBus.TDryBul = HDifTil[4].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1129 (size: 1) HDifTil[1].weaBus.TDryBul = HDifTil[5].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1131 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[2].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1132 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[3].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1133 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[4].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1134 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[5].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1126 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1145 (size: 1) HDifTil[1].weaBus.alt = HDirTil[3].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.alt = HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1146 (size: 1) HDifTil[1].weaBus.alt = HDirTil[4].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.alt = HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1147 (size: 1) HDifTil[1].weaBus.alt = HDirTil[5].weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.alt = HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1149 (size: 1) HDifTil[1].weaBus.alt = weaDat.weaBus.alt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.weaBus.alt, HDifTil[1].weaBus.alt Equations used to solve those variables: Equation 696 (size: 1): weaDat.altitude.y = weaDat.weaBus.alt Equation 1144 (size: 1): HDifTil[1].weaBus.alt = HDirTil[2].weaBus.alt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1151 (size: 1) HDifTil[1].weaBus.ceiHei = HDifTil[3].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1152 (size: 1) HDifTil[1].weaBus.ceiHei = HDifTil[4].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1153 (size: 1) HDifTil[1].weaBus.ceiHei = HDifTil[5].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1155 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[2].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1156 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[3].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1157 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[4].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1158 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[5].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1150 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1184 (size: 1) HDifTil[1].weaBus.lon = HDifTil[3].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1185 (size: 1) HDifTil[1].weaBus.lon = HDifTil[4].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1186 (size: 1) HDifTil[1].weaBus.lon = HDifTil[5].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1188 (size: 1) HDifTil[1].weaBus.lon = HDirTil[2].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1189 (size: 1) HDifTil[1].weaBus.lon = HDirTil[3].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1190 (size: 1) HDifTil[1].weaBus.lon = HDirTil[4].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1191 (size: 1) HDifTil[1].weaBus.lon = HDirTil[5].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1193 (size: 1) HDifTil[1].weaBus.lon = weaDat.weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.weaBus.lon, HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 693 (size: 1): weaDat.longitude.y = weaDat.weaBus.lon Equation 1183 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1195 (size: 1) HDifTil[1].weaBus.nOpa = HDifTil[3].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1196 (size: 1) HDifTil[1].weaBus.nOpa = HDifTil[4].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1197 (size: 1) HDifTil[1].weaBus.nOpa = HDifTil[5].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1199 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[2].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1200 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[3].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1201 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[4].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1202 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[5].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1194 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1206 (size: 1) HDifTil[1].weaBus.nTot = HDifTil[3].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1207 (size: 1) HDifTil[1].weaBus.nTot = HDifTil[4].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1208 (size: 1) HDifTil[1].weaBus.nTot = HDifTil[5].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1210 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[2].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1211 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[3].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1212 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[4].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1213 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[5].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1205 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1217 (size: 1) HDifTil[1].weaBus.pAtm = HDifTil[3].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1218 (size: 1) HDifTil[1].weaBus.pAtm = HDifTil[4].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1219 (size: 1) HDifTil[1].weaBus.pAtm = HDifTil[5].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1221 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[2].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1222 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[3].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1223 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[4].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1224 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[5].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1216 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1228 (size: 1) HDifTil[1].weaBus.relHum = HDifTil[3].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1229 (size: 1) HDifTil[1].weaBus.relHum = HDifTil[4].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1230 (size: 1) HDifTil[1].weaBus.relHum = HDifTil[5].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1232 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[2].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1233 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[3].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1234 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[4].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1235 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[5].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1227 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1239 (size: 1) HDifTil[1].weaBus.solAlt = HDifTil[3].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1240 (size: 1) HDifTil[1].weaBus.solAlt = HDifTil[4].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1241 (size: 1) HDifTil[1].weaBus.solAlt = HDifTil[5].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1243 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[2].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1244 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[3].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1245 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[4].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1246 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[5].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1238 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1250 (size: 1) HDifTil[1].weaBus.solDec = HDifTil[3].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1251 (size: 1) HDifTil[1].weaBus.solDec = HDifTil[4].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1252 (size: 1) HDifTil[1].weaBus.solDec = HDifTil[5].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1254 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[2].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1255 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[3].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1256 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[4].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1257 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[5].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1249 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1261 (size: 1) HDifTil[1].weaBus.solHouAng = HDifTil[3].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1262 (size: 1) HDifTil[1].weaBus.solHouAng = HDifTil[4].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1263 (size: 1) HDifTil[1].weaBus.solHouAng = HDifTil[5].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1265 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[2].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1266 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[3].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1267 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[4].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1268 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[5].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1260 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1288 (size: 1) HDifTil[1].weaBus.solZen = HDirTil[3].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.solZen = HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1289 (size: 1) HDifTil[1].weaBus.solZen = HDirTil[4].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.solZen = HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1290 (size: 1) HDifTil[1].weaBus.solZen = HDirTil[5].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.solZen = HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1294 (size: 1) HDifTil[1].weaBus.winDir = HDifTil[3].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1295 (size: 1) HDifTil[1].weaBus.winDir = HDifTil[4].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1296 (size: 1) HDifTil[1].weaBus.winDir = HDifTil[5].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1298 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[2].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1299 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[3].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1300 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[4].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1301 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[5].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1293 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1305 (size: 1) HDifTil[1].weaBus.winSpe = HDifTil[3].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1306 (size: 1) HDifTil[1].weaBus.winSpe = HDifTil[4].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1307 (size: 1) HDifTil[1].weaBus.winSpe = HDifTil[5].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1309 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[2].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1310 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[3].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1311 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[4].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase600FF.mo:212:3-216:20:writable] Warning: Equation 1312 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[5].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1304 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:866:3-871:47:writable] Warning: Equation 697 (size: 1) weaDat.chePre.pAtm = weaDat.weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.chePre.pAtm, weaDat.weaBus.pAtm Equations used to solve those variables: Equation 34 (size: 1): weaDat.chePre.pAtm = weaDat.chePre.PIn Equation 1226 (size: 1): HDifTil[1].weaBus.pAtm = weaDat.weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/SolarGeometry/BaseClasses/AltitudeAngle.mo:13:3-13:40:writable] Warning: Equation 57 (size: 1) weaDat.altAng.alt = 1.570796326794897 - weaDat.altAng.zen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.altAng.zen, weaDat.altAng.alt Equations used to solve those variables: Equation 648 (size: 1): weaDat.altAng.zen = weaDat.weaBus.solZen Equation 692 (size: 1): weaDat.altAng.alt = weaDat.weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/SolarGeometry/BaseClasses/ZenithAngle.mo:23:3-25:22:writable] Warning: Equation 58 (size: 1) weaDat.zenAng.zen = acos(cos(weaDat.zenAng.lat) * cos(weaDat.zenAng.decAng) * cos(weaDat.zenAng.solHouAng) + sin(weaDat.zenAng.lat) * sin(weaDat.zenAng.decAng)) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.zenAng.solHouAng, weaDat.zenAng.decAng, weaDat.zenAng.zen, weaDat.zenAng.lat Equations used to solve those variables: Equation 642 (size: 1): weaDat.decAng.decAng = weaDat.zenAng.decAng Equation 644 (size: 1): weaDat.solHouAng.solHouAng = weaDat.zenAng.solHouAng Equation 649 (size: 1): weaDat.altAng.zen = weaDat.zenAng.zen Equation 695 (size: 1): weaDat.latitude.y = weaDat.zenAng.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/SolarGeometry/BaseClasses/Declination.mo:16:3-17:13:writable] Warning: Equation 59 (size: 1) weaDat.decAng.decAng = asin((-0.3979486313076103) * cos(0.01720242383895848 * (10.0 + 1.157407407407407e-05 * weaDat.decAng.nDay))) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.decAng.nDay, weaDat.decAng.decAng Equations used to solve those variables: Equation 626 (size: 1): weaDat.add30Min.u2 = weaDat.decAng.nDay Equation 641 (size: 1): weaDat.decAng.decAng = weaDat.weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:711:3-713:80:writable] Warning: Equation 675 (size: 1) weaDat.HGloHor_in = weaDat.souSelRad.HGloHorIn is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.souSelRad.HGloHorIn, weaDat.HGloHor_in Equations used to solve those variables: Equation 620 (size: 1): weaDat.souSelRad.HGloHorIn = weaDat.souSelRad.HGloHor_in_internal Equation 1387 (size: 1): souRad.y[2] = weaDat.HGloHor_in [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/BaseClasses/SolarTime.mo:16:3-16:68:writable] Warning: Equation 53 (size: 1) weaDat.solTim.solTim = weaDat.solTim.locTim + weaDat.solTim.equTim is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.solTim.locTim, weaDat.solTim.equTim, weaDat.solTim.solTim Equations used to solve those variables: Equation 635 (size: 1): weaDat.eqnTim.eqnTim = weaDat.solTim.equTim Equation 636 (size: 1): weaDat.locTim.locTim = weaDat.solTim.locTim Equation 645 (size: 1): weaDat.solHouAng.solTim = weaDat.solTim.solTim [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/BaseClasses/SourceSelector.mo:23:3-23:19:writable] Warning: Equation 615 (size: 1) weaDat.TBlaSkySel.uFil = weaDat.TBlaSkySel.y is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.TBlaSkySel.y, weaDat.TBlaSkySel.uFil Equations used to solve those variables: Equation 657 (size: 1): weaDat.TBlaSkySel.y = weaDat.cheTemBlaSky.TIn Equation 658 (size: 1): weaDat.TBlaSkyCom.TBlaSky = weaDat.TBlaSkySel.uFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/BaseClasses/SourceSelectorRadiation.mo:109:3-109:42:writable] Warning: Equation 621 (size: 1) weaDat.souSelRad.HDirNorIn = weaDat.souSelRad.HDirNor_in_internal is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.souSelRad.HDirNor_in_internal, weaDat.souSelRad.HDirNorIn Equations used to solve those variables: Equation 29 (size: 1): weaDat.souSelRad.HDifHor = max(0.0, weaDat.souSelRad.HGloHor_in_internal - weaDat.souSelRad.HDirNor_in_internal * cos(weaDat.souSelRad.zen)) Equation 674 (size: 1): weaDat.HDirNor_in = weaDat.souSelRad.HDirNorIn [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:640:3-641:71:writable] Warning: Equation 655 (size: 1) weaDat.TDryBulSel.y = weaDat.cheTemDryBul.TIn is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.TDryBulSel.y, weaDat.cheTemDryBul.TIn Equations used to solve those variables: Equation 32 (size: 1): weaDat.cheTemDryBul.TDryBul = weaDat.cheTemDryBul.TIn Equation 613 (size: 1): weaDat.TDryBulSel.uCon = weaDat.TDryBulSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:667:3-668:55:writable] Warning: Equation 663 (size: 1) weaDat.ceiHeiSel.uFil = weaDat.datRea.y[16] is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.datRea.y[16], weaDat.ceiHeiSel.uFil Equations used to solve those variables: Equation 16 (size: 1): weaDat.datRea.y[16] = Modelica.Blocks.Tables.Internal.getTable1DValue(weaDat.datRea.tableID, 16, weaDat.datRea.u) Equation 622 (size: 1): weaDat.ceiHeiSel.uFil = weaDat.ceiHeiSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:681:3-682:55:writable] Warning: Equation 668 (size: 1) weaDat.datRea.y[12] = weaDat.winSpeSel.uFil is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.datRea.y[12], weaDat.winSpeSel.uFil Equations used to solve those variables: Equation 12 (size: 1): weaDat.datRea.y[12] = Modelica.Blocks.Tables.Internal.getTable1DValue(weaDat.datRea.tableID, 12, weaDat.datRea.u) Equation 617 (size: 1): weaDat.winSpeSel.uFil = weaDat.winSpeSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Math.mo:145:7-145:49:writable] Warning: Equation 54 (size: 1) weaDat.conWinDir.y = Modelica.Units.Conversions.from_deg(weaDat.conWinDir.u) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.conWinDir.u, weaDat.conWinDir.y Equations used to solve those variables: Equation 637 (size: 1): weaDat.conWinDir.u = weaDat.datRea.y[11] Equation 670 (size: 1): weaDat.conWinDir.y = weaDat.winDirSel.uFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Math.mo:552:5-552:12:writable] Warning: Equation 65 (size: 1) weaDat.conRelHum.y = weaDat.conRelHum.k * weaDat.conRelHum.u is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.conRelHum.u, weaDat.conRelHum.y Equations used to solve those variables: Equation 640 (size: 1): weaDat.conRelHum.u = weaDat.datRea.y[3] Equation 660 (size: 1): weaDat.conRelHum.y = weaDat.relHumSel.uFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Math.mo:552:5-552:12:writable] Warning: Equation 70 (size: 1) weaDat.conTotSkyCov.y = weaDat.conTotSkyCov.k * weaDat.conTotSkyCov.u is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.conTotSkyCov.u, weaDat.conTotSkyCov.y Equations used to solve those variables: Equation 664 (size: 1): weaDat.conTotSkyCov.y = weaDat.totSkyCovSel.uFil Equation 667 (size: 1): weaDat.conTotSkyCov.u = weaDat.datRea.y[13] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:636:3-637:56:writable] Warning: Equation 654 (size: 1) weaDat.TDewPoiSel.uFil = weaDat.conTDewPoi.y is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.TDewPoiSel.uFil, weaDat.conTDewPoi.y Equations used to solve those variables: Equation 56 (size: 1): weaDat.conTDewPoi.y = Modelica.Units.Conversions.from_degC(weaDat.conTDewPoi.u) Equation 614 (size: 1): weaDat.TDewPoiSel.uFil = weaDat.TDewPoiSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:660:3-662:70:writable] Warning: Equation 661 (size: 1) weaDat.conOpaSkyCov.y = weaDat.opaSkyCovSel.uFil is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.opaSkyCovSel.uFil, weaDat.conOpaSkyCov.y Equations used to solve those variables: Equation 71 (size: 1): weaDat.conOpaSkyCov.y = weaDat.conOpaSkyCov.k * weaDat.conOpaSkyCov.u Equation 624 (size: 1): weaDat.opaSkyCovSel.uFil = weaDat.opaSkyCovSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/BoundaryConditions/WeatherData/ReaderTMY3.mo:698:3-699:59:writable] Warning: Equation 673 (size: 1) weaDat.HInfHor_in = weaDat.horInfRadSel.uCon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.horInfRadSel.uCon, weaDat.HInfHor_in Equations used to solve those variables: Equation 619 (size: 1): weaDat.horInfRadSel.uCon = weaDat.horInfRadSel.y Equation 1385 (size: 1): division.y = weaDat.HInfHor_in