Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr OpenHydraulics_OpenHydraulics.Circuits.PressureCompensatedLoadSensing.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo", uses=false) Using package OpenHydraulics with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo) Using package ModelicaServices with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo) Using package Modelica with version 3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo) Using package Complex with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo) Running command: "" <> buildModelFMU(OpenHydraulics.Circuits.PressureCompensatedLoadSensing,fileNamePrefix="OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(OpenHydraulics.Circuits.PressureCompensatedLoadSensing,fileNamePrefix="OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo): time 0.001752/0.001752, allocations: 146 kB / 12.7 MB, free: 2.617 MB / 13.93 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8490:35-8490:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nom...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8600:35-8600:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nomi...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8738:35-8738:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of a pr...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8793:35-8793:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss with linear or quadra...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:14-570:31:writable] Warning: Treating .0158271919734802 as 0.0158271919734802. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:48-570:65:writable] Warning: Treating .0942738402188500 as 0.0942738402188500. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:13-571:29:writable] Warning: Treating .155071987336585 as 0.155071987336585. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:47-571:63:writable] Warning: Treating .188821573960182 as 0.188821573960182. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:9-572:25:writable] Warning: Treating .199773405226859 as 0.199773405226859. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:42-572:58:writable] Warning: Treating .224926465333340 as 0.224926465333340. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:75-572:91:writable] Warning: Treating .242611071901408 as 0.242611071901408. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo): time 1.233/1.233, allocations: 150.5 MB / 163.7 MB, free: 2.375 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo): time 0.00143/0.00143, allocations: 74.36 kB / 198.8 MB, free: 12.98 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo): time 0.1729/0.1729, allocations: 11.7 MB / 245.5 MB, free: 34.09 MB / 202.7 MB Notification: Performance of FrontEnd - loaded program: time 4.234e-05/4.236e-05, allocations: 7.984 kB / 290.6 MB, free: 11.3 MB / 218.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09259/0.09265, allocations: 37.14 MB / 327.7 MB, free: 6.117 MB / 250.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3065/0.3992, allocations: 71.26 MB / 399 MB, free: 8.262 MB / 266.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002348/0.3995, allocations: 70.47 kB / 399.1 MB, free: 8.23 MB / 266.7 MB Notification: Performance of FrontEnd - DAE generated: time 0.4639/0.8634, allocations: 126.8 MB / 0.5136 GB, free: 38.22 MB / 330.7 MB Notification: Performance of FrontEnd: time 2.515e-06/0.8634, allocations: 0 / 0.5136 GB, free: 38.22 MB / 330.7 MB Notification: Performance of Transformations before backend: time 0.0004208/0.8638, allocations: 112.5 kB / 0.5137 GB, free: 38.21 MB / 330.7 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 902 * Number of variables: 902 Notification: Performance of Generate backend data structure: time 0.01122/0.8751, allocations: 4.24 MB / 0.5178 GB, free: 35.95 MB / 330.7 MB Notification: Performance of prepare preOptimizeDAE: time 4.361e-05/0.8751, allocations: 9.5 kB / 0.5178 GB, free: 35.95 MB / 330.7 MB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.001494/0.8766, allocations: 490.6 kB / 0.5183 GB, free: 35.89 MB / 330.7 MB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.001575/0.8782, allocations: 0.5505 MB / 0.5188 GB, free: 35.63 MB / 330.7 MB Notification: Performance of preOpt evaluateParameters (simulation): time 0.006625/0.8848, allocations: 2.965 MB / 0.5217 GB, free: 34.89 MB / 330.7 MB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0004623/0.8853, allocations: 397.2 kB / 0.5221 GB, free: 34.64 MB / 330.7 MB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001086/0.8864, allocations: 374.1 kB / 0.5225 GB, free: 34.51 MB / 330.7 MB Notification: Performance of preOpt clockPartitioning (simulation): time 0.007633/0.8941, allocations: 4.174 MB / 0.5266 GB, free: 32.73 MB / 330.7 MB Notification: Performance of preOpt findStateOrder (simulation): time 7.808e-05/0.8942, allocations: 2.406 kB / 0.5266 GB, free: 32.73 MB / 330.7 MB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0003576/0.8945, allocations: 145.3 kB / 0.5267 GB, free: 32.62 MB / 330.7 MB Notification: Performance of preOpt inlineArrayEqn (simulation): time 7.755e-05/0.8946, allocations: 89.14 kB / 0.5268 GB, free: 32.62 MB / 330.7 MB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.006527/0.9012, allocations: 3.785 MB / 0.5305 GB, free: 31.04 MB / 330.7 MB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.02443/0.9256, allocations: 20.33 MB / 0.5503 GB, free: 15.96 MB / 330.7 MB Notification: Performance of preOpt comSubExp (simulation): time 0.004931/0.9306, allocations: 4.047 MB / 0.5543 GB, free: 13.77 MB / 330.7 MB Notification: Performance of preOpt resolveLoops (simulation): time 0.002199/0.9328, allocations: 1.68 MB / 0.5559 GB, free: 13.04 MB / 330.7 MB Notification: Performance of preOpt evalFunc (simulation): time 0.0002888/0.9331, allocations: 156.1 kB / 0.5561 GB, free: 12.94 MB / 330.7 MB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.002577/0.9357, allocations: 1.928 MB / 0.558 GB, free: 12.09 MB / 330.7 MB Notification: Performance of pre-optimization done (n=324): time 4.789e-06/0.9357, allocations: 0 / 0.558 GB, free: 12.09 MB / 330.7 MB Notification: Performance of matching and sorting (n=351): time 0.02414/0.9599, allocations: 13.28 MB / 0.5709 GB, free: 5.047 MB / 330.7 MB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001337/0.96, allocations: 437.2 kB / 0.5713 GB, free: 4.566 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Blocks/Continuous.mo:860:5-860:57:writable] Warning: Parameter PCLSPump.swashPlatePD.yMax has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Blocks/Continuous.mo:852:5-855:71:writable] Warning: Parameter PCLSPump.swashPlatePD.Ti has no value, and is fixed during initialization (fixed=true), using available start value (start=0.5) as default value. Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00425/0.9643, allocations: 2.928 MB / 0.5742 GB, free: 3.504 MB / 330.7 MB Notification: Performance of collectPreVariables (initialization): time 0.0004183/0.9647, allocations: 98.42 kB / 0.5743 GB, free: 3.426 MB / 330.7 MB Notification: Performance of collectInitialEqns (initialization): time 0.001213/0.9659, allocations: 1.777 MB / 0.576 GB, free: 2.051 MB / 330.7 MB Notification: Performance of collectInitialBindings (initialization): time 0.0008254/0.9668, allocations: 1.163 MB / 0.5772 GB, free: 1.141 MB / 330.7 MB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0001869/0.967, allocations: 69.34 kB / 0.5772 GB, free: 1.09 MB / 330.7 MB Notification: Performance of setup shared object (initialization): time 0.0001665/0.9671, allocations: 436.4 kB / 0.5776 GB, free: 0.7266 MB / 330.7 MB Notification: Performance of preBalanceInitialSystem (initialization): time 0.002232/0.9694, allocations: 1.517 MB / 0.5791 GB, free: 32 kB / 330.7 MB Notification: Performance of partitionIndependentBlocks (initialization): time 0.009057/0.9785, allocations: 2.549 MB / 0.5816 GB, free: 15.1 MB / 346.7 MB Notification: Performance of analyzeInitialSystem (initialization): time 0.003154/0.9816, allocations: 1.908 MB / 0.5835 GB, free: 13.27 MB / 346.7 MB Notification: Performance of solveInitialSystemEqSystem (initialization): time 1.183e-05/0.9817, allocations: 11.95 kB / 0.5835 GB, free: 13.25 MB / 346.7 MB Notification: Performance of matching and sorting (n=441) (initialization): time 0.0089/0.9906, allocations: 4.815 MB / 0.5882 GB, free: 8.621 MB / 346.7 MB Notification: Performance of prepare postOptimizeDAE: time 0.0001771/0.9908, allocations: 292.6 kB / 0.5885 GB, free: 8.281 MB / 346.7 MB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 3.475e-05/0.9909, allocations: 16 kB / 0.5885 GB, free: 8.266 MB / 346.7 MB Notification: Performance of postOpt tearingSystem (initialization): time 0.0006587/0.9915, allocations: 290.1 kB / 0.5888 GB, free: 7.996 MB / 346.7 MB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.003131/0.9947, allocations: 0.7606 MB / 0.5895 GB, free: 7.348 MB / 346.7 MB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.2296/1.224, allocations: 8.119 MB / 0.5974 GB, free: 48.26 MB / 346.7 MB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.005412/1.23, allocations: 400.8 kB / 0.5978 GB, free: 48.26 MB / 346.7 MB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0009853/1.231, allocations: 173.6 kB / 0.598 GB, free: 48.26 MB / 346.7 MB Warning: Assuming fixed start value for the following 11 variables: constantSpeed.phi:VARIABLE(unit = "rad" ) "Angle of flange with respect to support (= flange.phi - support.phi)" type: Real valve4way3pos.reliefA2T.valvePosition:VARIABLE(start = 0.0 ) "Normalized valve position (between 0 and 1)" type: Real valve4way3pos.reliefB2T.valvePosition:VARIABLE(start = 0.0 ) "Normalized valve position (between 0 and 1)" type: Real PCLSPump.portP.p:VARIABLE(flow=false min = max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, 2000.0))))))))))))))))))))))))))))))))))))))))))))))))) max = min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, 1000000000.0))))))))))))))))))))))))))))))))))))))))))))))))) start = PCLSPump.fluidPower2MechRotVar.p_init unit = "Pa" nominal = 100000.0 stateSelect=StateSelect.prefer ) "Pressure in the connection point" type: Real doubleActingCylinder.damper.v_rel:VARIABLE(start = 0.0 unit = "m/s" stateSelect=StateSelect.prefer ) "Relative velocity (= der(s_rel))" type: Real doubleActingCylinder.cushionRod.flowFraction:VARIABLE(protected = true ) "fraction of flow allowed by cushion" type: Real doubleActingCylinder.cushionRod.reliefValve.valvePosition:VARIABLE(start = 0.0 ) "Normalized valve position (between 0 and 1)" type: Real doubleActingCylinder.cushionHead.flowFraction:VARIABLE(protected = true ) "fraction of flow allowed by cushion" type: Real doubleActingCylinder.cushionHead.reliefValve.valvePosition:VARIABLE(start = 0.0 ) "Normalized valve position (between 0 and 1)" type: Real doubleActingCylinder.cylinderChamberRod.port[3].p:VARIABLE(flow=false min = max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, 2000.0)))))))))))))))) max = min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, 1000000000.0)))))))))))))))) start = doubleActingCylinder.cushionRod.cushionRestriction.p_init unit = "Pa" nominal = 100000.0 stateSelect=StateSelect.prefer ) "Pressure in the connection point" type: Real [3] reliefValve.valvePosition:VARIABLE(start = 0.0 ) "Normalized valve position (between 0 and 1)" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 62 * Number of states: 0 () * Number of discrete variables: 42 (valve4way3pos.reliefA2T.variableRestriction.data.zetaLaminarKnown,valve4way3pos.reliefB2T.variableRestriction.data.zetaLaminarKnown,valve4way3pos.checkT2A.variableRestriction.data.zetaLaminarKnown,valve4way3pos.checkT2B.variableRestriction.data.zetaLaminarKnown,valve4way3pos.A2T.data.zetaLaminarKnown,valve4way3pos.P2B.data.zetaLaminarKnown,valve4way3pos.B2T.data.zetaLaminarKnown,valve4way3pos.P2A.data.zetaLaminarKnown,PCLSPump.mechanicalPumpLosses.free,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionRod.cushionRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionHead.cushionRestriction.data.zetaLaminarKnown,reliefValve.variableRestriction.data.zetaLaminarKnown,$whenCondition2,$whenCondition1,$whenCondition3,$whenCondition4,reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cylinderChamberHead.empty,doubleActingCylinder.cylinderChamberRod.empty,doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.cushionTableBlock.tableID,doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.cushionTableBlock.tableID,$PRE.PCLSPump.mechanicalPumpLosses.startForward,PCLSPump.mechanicalPumpLosses.startForward,$PRE.PCLSPump.mechanicalPumpLosses.startBackward,PCLSPump.mechanicalPumpLosses.startBackward,PCLSPump.mechanicalPumpLosses.locked,$PRE.PCLSPump.mechanicalPumpLosses.mode,PCLSPump.mechanicalPumpLosses.mode,valve4way3pos.P2A.MeteringTable.tableID,valve4way3pos.B2T.MeteringTable.tableID,valve4way3pos.P2B.MeteringTable.tableID,valve4way3pos.A2T.MeteringTable.tableID,valve4way3pos.checkT2B.variableRestriction.MeteringTable.tableID,valve4way3pos.checkT2A.variableRestriction.MeteringTable.tableID,valve4way3pos.reliefB2T.variableRestriction.MeteringTable.tableID,valve4way3pos.reliefA2T.variableRestriction.MeteringTable.tableID) * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (421): * Single equations (assignments): 406 * Array equations: 0 * Algorithm blocks: 10 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 5 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 4 {(1,100.0%) 6,(1,100.0%) 5,(1,100.0%) 3,(1,100.0%) 3} * Non-linear torn systems: 1 {1 3} Notification: Performance of prepare postOptimizeDAE: time 0.001867/1.233, allocations: 0.8904 MB / 0.5989 GB, free: 47.78 MB / 346.7 MB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001381/1.234, allocations: 428 kB / 0.5993 GB, free: 47.78 MB / 346.7 MB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01069/1.245, allocations: 5.189 MB / 0.6043 GB, free: 46.97 MB / 346.7 MB Notification: Performance of postOpt inlineArrayEqn (simulation): time 4.286e-05/1.245, allocations: 37.53 kB / 0.6044 GB, free: 46.97 MB / 346.7 MB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.255e-05/1.245, allocations: 5.594 kB / 0.6044 GB, free: 46.97 MB / 346.7 MB Notification: Performance of postOpt simplifysemiLinear (simulation): time 3.999e-05/1.245, allocations: 17.27 kB / 0.6044 GB, free: 46.97 MB / 346.7 MB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.01866/1.263, allocations: 10.79 MB / 0.6149 GB, free: 44.94 MB / 346.7 MB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.556e-05/1.264, allocations: 6.188 kB / 0.6149 GB, free: 44.94 MB / 346.7 MB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.002595/1.266, allocations: 0.6328 MB / 0.6156 GB, free: 44.94 MB / 346.7 MB Notification: Performance of postOpt tearingSystem (simulation): time 0.000482/1.267, allocations: 264.8 kB / 0.6158 GB, free: 44.9 MB / 346.7 MB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0004135/1.267, allocations: 110.7 kB / 0.6159 GB, free: 44.9 MB / 346.7 MB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.004911/1.272, allocations: 7.695 MB / 0.6234 GB, free: 38.45 MB / 346.7 MB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 9.147e-06/1.272, allocations: 12.02 kB / 0.6234 GB, free: 38.45 MB / 346.7 MB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01346/1.285, allocations: 7.607 MB / 0.6309 GB, free: 36.77 MB / 346.7 MB Notification: Performance of postOpt removeConstants (simulation): time 0.002755/1.288, allocations: 0.9716 MB / 0.6318 GB, free: 36.61 MB / 346.7 MB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0007587/1.289, allocations: 85.33 kB / 0.6319 GB, free: 36.61 MB / 346.7 MB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.002236/1.291, allocations: 271.1 kB / 0.6322 GB, free: 36.61 MB / 346.7 MB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0006107/1.292, allocations: 374.7 kB / 0.6325 GB, free: 36.61 MB / 346.7 MB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0002865/1.292, allocations: 155.7 kB / 0.6327 GB, free: 36.61 MB / 346.7 MB Notification: Performance of sorting global known variables: time 0.003368/1.296, allocations: 2.256 MB / 0.6349 GB, free: 36.45 MB / 346.7 MB Notification: Performance of sort global known variables: time 2.9e-07/1.296, allocations: 0 / 0.6349 GB, free: 36.45 MB / 346.7 MB Notification: Performance of remove unused functions: time 0.004216/1.3, allocations: 1.168 MB / 0.636 GB, free: 36.44 MB / 346.7 MB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 20 * Number of states: 20 (reliefValve.valvePosition,doubleActingCylinder.port_a.p,doubleActingCylinder.port_b.p,doubleActingCylinder.cylinderChamberHead.port[3].p,doubleActingCylinder.cylinderChamberRod.port[3].p,doubleActingCylinder.cushionHead.reliefValve.valvePosition,doubleActingCylinder.cushionHead.flowFraction,doubleActingCylinder.cushionRod.reliefValve.valvePosition,doubleActingCylinder.cushionRod.flowFraction,doubleActingCylinder.damper.s_rel,doubleActingCylinder.damper.v_rel,PCLSPump.swashPlatePD.D.x,PCLSPump.portP.p,PCLSPump.portLS.p,circuitTank.volumeOpen.m,valve4way3pos.dynamicResponse.y,valve4way3pos.dynamicResponse.yd,valve4way3pos.reliefB2T.valvePosition,valve4way3pos.reliefA2T.valvePosition,constantSpeed.phi) * Number of discrete variables: 25 ($whenCondition2,$whenCondition1,$whenCondition3,$whenCondition4,reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cylinderChamberHead.empty,doubleActingCylinder.cylinderChamberRod.empty,doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.cushionTableBlock.tableID,doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.cushionTableBlock.tableID,PCLSPump.mechanicalPumpLosses.startForward,PCLSPump.mechanicalPumpLosses.startBackward,PCLSPump.mechanicalPumpLosses.locked,PCLSPump.mechanicalPumpLosses.mode,valve4way3pos.P2A.MeteringTable.tableID,valve4way3pos.B2T.MeteringTable.tableID,valve4way3pos.P2B.MeteringTable.tableID,valve4way3pos.A2T.MeteringTable.tableID,valve4way3pos.checkT2B.variableRestriction.MeteringTable.tableID,valve4way3pos.checkT2A.variableRestriction.MeteringTable.tableID,valve4way3pos.reliefB2T.variableRestriction.MeteringTable.tableID,valve4way3pos.reliefA2T.variableRestriction.MeteringTable.tableID) * Number of discrete states: 5 (PCLSPump.mechanicalPumpLosses.mode,PCLSPump.mechanicalPumpLosses.startBackward,PCLSPump.mechanicalPumpLosses.startForward,$whenCondition3,$whenCondition4) * Top-level inputs: 0 Notification: Strong component statistics for simulation (373): * Single equations (assignments): 343 * Array equations: 0 * Algorithm blocks: 10 * Record equations: 0 * When equations: 15 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 5 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 4 {(1,100.0%) 5,(1,100.0%) 3,(1,100.0%) 3,(1,100.0%) 2} * Non-linear torn systems: 1 {1 3} Notification: Performance of Backend phase and start with SimCode phase: time 0.01111/1.311, allocations: 9.822 MB / 0.6456 GB, free: 32.83 MB / 346.7 MB Notification: Performance of simCode: created initialization part: time 0.006742/1.318, allocations: 4.622 MB / 0.6501 GB, free: 31.58 MB / 346.7 MB Notification: Performance of simCode: created event and clocks part: time 1.067e-05/1.318, allocations: 4.406 kB / 0.6501 GB, free: 31.58 MB / 346.7 MB Notification: Performance of simCode: created simulation system equations: time 0.004398/1.322, allocations: 3.154 MB / 0.6532 GB, free: 30.36 MB / 346.7 MB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.0103/1.332, allocations: 1.78 MB / 0.6549 GB, free: 30.29 MB / 346.7 MB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.01971/1.352, allocations: 7.978 MB / 0.6627 GB, free: 27.97 MB / 346.7 MB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.002446/1.355, allocations: 2.634 MB / 0.6653 GB, free: 26.99 MB / 346.7 MB Notification: Performance of simCode: alias equations: time 0.004102/1.359, allocations: 0.7282 MB / 0.666 GB, free: 26.87 MB / 346.7 MB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.002959/1.362, allocations: 1.908 MB / 0.6679 GB, free: 25.4 MB / 346.7 MB Notification: Performance of SimCode: time 1.903e-06/1.362, allocations: 0 / 0.6679 GB, free: 25.4 MB / 346.7 MB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.3756/1.737, allocations: 111.7 MB / 0.777 GB, free: 57.07 MB / 362.7 MB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.0001443/1.738, allocations: 227.5 kB / 0.7772 GB, free: 56.84 MB / 362.7 MB Error: Error building simulator. Build log: clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing.c:7: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:1426:11: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_k1 == 0.0)) ~~~~^~~~~~ OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:1426:11: note: remove extraneous parentheses around the comparison to silence this warning if((_k1 == 0.0)) ~ ^ ~ OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:1426:11: note: use '=' to turn this equality comparison into an assignment if((_k1 == 0.0)) ^~ = 3 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_records.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_records.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_01exo.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_01exo.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_01exo.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_02nls.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_02nls.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_02nls.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_03lsy.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_03lsy.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_03lsy.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_04set.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_04set.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_04set.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_05evt.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_05evt.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_05evt.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_06inz.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_06inz.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_06inz.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_07dly.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_07dly.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_07dly.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_08bnd.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_08bnd.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_08bnd.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_09alg.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_09alg.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_09alg.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_10asr.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_10asr.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_10asr.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_11mix.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_11mix.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_11mix.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_12jac.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_12jac.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_12jac.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_13opt.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_13opt.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_13opt.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_14lnz.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_14lnz.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_14lnz.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_15syn.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_15syn.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_15syn.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_16dae.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_16dae.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_16dae.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_17inl.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_17inl.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_17inl.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_init_fmu.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_init_fmu.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -c -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_FMU.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_FMU.c In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_FMU.c:54: ./fmi-export/fmu2_model_interface.c.inc:73:11: warning: enumeration value 'modelSlaveInitialized' not handled in switch [-Wswitch] switch (comp->state) ^ ./fmi-export/fmu2_model_interface.c.inc:162:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 4 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing.so OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_records.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_01exo.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_02nls.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_03lsy.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_04set.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_05evt.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_06inz.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_07dly.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_08bnd.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_09alg.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_10asr.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_11mix.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_12jac.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_13opt.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_14lnz.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_15syn.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_16dae.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_17inl.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_init_fmu.o OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/Circuits" -Wl,-Bstatic "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -lm -lpthread -rdynamic -Wl,--no-undefined /usr/bin/ld: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libModelicaExternalC.a(ModelicaInternal.o): in function `ModelicaInternal_temporaryFileName': ModelicaInternal.c:(.text+0x5a4): warning: the use of `tmpnam' is dangerous, better use `mkstemp' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1D24doubleActingCylinder24cushionHead24cushionTableBlock_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x44): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1D24doubleActingCylinder24cushionHead24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xb5): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1D24doubleActingCylinder24cushionHead24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xcb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1D24doubleActingCylinder24cushionRod24cushionTableBlock_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x14a): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1D24doubleActingCylinder24cushionRod24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x1bb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1D24doubleActingCylinder24cushionRod24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x1d1): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionHead24cushionRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x250): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionHead24cushionRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x2c1): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionHead24cushionRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x2d7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionHead24reliefValve24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x356): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionHead24reliefValve24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x3c7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionHead24reliefValve24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x3dd): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionRod24cushionRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x45c): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionRod24cushionRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x4cd): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionRod24cushionRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x4e3): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionRod24reliefValve24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x562): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionRod24reliefValve24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x5d3): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24doubleActingCylinder24cushionRod24reliefValve24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x5e9): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24reliefValve24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x668): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24reliefValve24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x6d9): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24reliefValve24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x6ef): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24A2T24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x76e): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24A2T24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x7df): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24A2T24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x7f5): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24B2T24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x874): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24B2T24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x8e5): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24B2T24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x8fb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24P2A24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x97a): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24P2A24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0x9eb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24P2A24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xa01): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24P2B24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xa80): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24P2B24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xaf1): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24P2B24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xb07): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24checkT2A24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xb86): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24checkT2A24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xbf7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24checkT2A24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xc0d): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24checkT2B24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xc8c): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24checkT2B24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xcfd): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24checkT2B24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xd13): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24reliefA2T24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xd92): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24reliefA2T24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xe03): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24reliefA2T24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xe19): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24reliefB2T24variableRestriction24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xe98): undefined reference to `ModelicaTables_CombiTable1D_init' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `omc_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24reliefB2T24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xf09): undefined reference to `ModelicaTables_CombiTable1D_interpolate' /usr/bin/ld: OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.o: in function `boxptr_Modelica_Blocks_Tables_D_CombiTable1Ds24valve4way3pos24reliefB2T24variableRestriction24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_PressureCompensatedLoadSensing_functions.c:(.text+0xf1f): undefined reference to `ModelicaTables_CombiTable1D_interpolate' clang: error: linker command failed with exit code 1 (use -v to see invocation) make: *** [Makefile:32: nozip] Error 1