Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="IDEAS_dev_IDEAS_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="IDEAS_dev_IDEAS_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001302/0.001301, allocations: 174.7 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo): time 0.722/0.722, allocations: 133.4 MB / 146.7 MB, free: 10.8 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.454/1.454, allocations: 221.3 MB / 400.4 MB, free: 5.84 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009391/0.0009391, allocations: 97.89 kB / 483.3 MB, free: 5.891 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 3.085e-05/3.088e-05, allocations: 2.156 kB / 0.5601 GB, free: 87.82 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1528/0.1529, allocations: 82.32 MB / 0.6405 GB, free: 7.699 MB / 442.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.6053/0.7582, allocations: 142.5 MB / 0.7797 GB, free: 12.04 MB / 0.5105 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002681/0.7585, allocations: 107.3 kB / 0.7798 GB, free: 11.98 MB / 0.5105 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years Notification: Performance of FrontEnd: time 0.03301/0.7915, allocations: 11.79 MB / 0.7914 GB, free: 2.387 MB / 0.5105 GB