Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr HanserModelica_HanserModelica.FirstSteps.Electrical3.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/HanserModelica 2.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package HanserModelica with version 2.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/HanserModelica 2.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(HanserModelica.FirstSteps.Electrical3,fileNamePrefix="HanserModelica_HanserModelica_FirstSteps_Electrical3",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(HanserModelica.FirstSteps.Electrical3,fileNamePrefix="HanserModelica_HanserModelica_FirstSteps_Electrical3",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001104/0.001103, allocations: 174.9 kB / 12.73 MB, free: 2.59 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/HanserModelica 2.0.0-master/package.mo): time 0.03767/0.03767, allocations: 8.708 MB / 21.97 MB, free: 3.707 MB / 18.57 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.387/1.387, allocations: 221.3 MB / 246 MB, free: 3.559 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008486/0.0008485, allocations: 90.16 kB / 299.1 MB, free: 2.996 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 2.765e-05/2.767e-05, allocations: 0 / 359.6 MB, free: 6.426 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2727/0.2727, allocations: 52.54 MB / 412.2 MB, free: 22.43 MB / 298.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo:2:1-9040:13:writable] Error: Class SIunits.Resistance not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/HanserModelica 2.0.0-master/FirstSteps/Electrical3.mo:5:3-5:60:writable] Error: Class Modelica.SIunits.Resistance not found in scope HanserModelica.FirstSteps.Electrical3. Error: Error occurred while flattening model HanserModelica.FirstSteps.Electrical3 Notification: Performance of FrontEnd: time 0.1027/0.3755, allocations: 75.13 MB / 487.3 MB, free: 11.2 MB / 362.7 MB