Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneTwoIdenticalOutputVariables",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneTwoIdenticalOutputVariables",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.732/1.732, allocations: 285.4 MB / 298 MB, free: 5.961 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001091/0.001091, allocations: 176.9 kB / 366.4 MB, free: 2.066 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.726/1.726, allocations: 205.1 MB / 0.6248 GB, free: 7.73 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001004/0.001004, allocations: 91.98 kB / 0.738 GB, free: 40.25 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.397e-05/4.399e-05, allocations: 0 / 0.8584 GB, free: 12.99 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9541/0.9542, allocations: 115.3 MB / 0.971 GB, free: 77.77 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.553/7.507, allocations: 2.113 GB / 3.084 GB, free: 1.133 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004931/7.508, allocations: 95.94 kB / 3.084 GB, free: 1.039 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoIdenticalOutputVariables Notification: Performance of FrontEnd: time 1.182/8.69, allocations: 155.6 MB / 3.236 GB, free: 237.7 MB / 0.948 GB