Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingWinter",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingWinter",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.833/1.833, allocations: 285.4 MB / 298 MB, free: 5.98 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001487/0.001488, allocations: 172.8 kB / 366.4 MB, free: 2.082 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.17/2.17, allocations: 205.1 MB / 0.6248 GB, free: 7.727 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001144/0.001144, allocations: 88.56 kB / 0.738 GB, free: 40.22 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.961e-05/4.983e-05, allocations: 4 kB / 0.8584 GB, free: 12.96 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9295/0.9296, allocations: 115.3 MB / 0.971 GB, free: 77.88 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.511/7.441, allocations: 2.132 GB / 3.103 GB, free: 340.6 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000399/7.441, allocations: 97.16 kB / 3.103 GB, free: 340.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter Notification: Performance of FrontEnd: time 7.652/15.09, allocations: 1.631 GB / 4.734 GB, free: 114.8 MB / 0.9792 GB