Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_reverseFlow",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_reverseFlow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.609/1.609, allocations: 285.4 MB / 298 MB, free: 5.902 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001545/0.001545, allocations: 180.8 kB / 366.4 MB, free: 2.062 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.51/1.51, allocations: 205.1 MB / 0.6248 GB, free: 7.723 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009436/0.0009436, allocations: 86.78 kB / 0.738 GB, free: 40.23 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.825e-05/3.843e-05, allocations: 4 kB / 0.8584 GB, free: 12.97 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6928/0.6928, allocations: 115.3 MB / 0.971 GB, free: 77.95 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.069/1.761, allocations: 422.4 MB / 1.384 GB, free: 137.4 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000268/1.762, allocations: 90.02 kB / 1.384 GB, free: 137.4 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.1536/1.915, allocations: 84.37 MB / 1.466 GB, free: 66.74 MB / 0.8542 GB