Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.677/1.677, allocations: 285.4 MB / 298 MB, free: 5.969 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001109/0.001109, allocations: 184.8 kB / 366.4 MB, free: 2.09 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.655/1.655, allocations: 205.1 MB / 0.6248 GB, free: 7.75 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009007/0.0009009, allocations: 89.36 kB / 0.738 GB, free: 40.26 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.09e-05/3.115e-05, allocations: 4 kB / 0.8584 GB, free: 12.99 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5897/0.5898, allocations: 115.3 MB / 0.971 GB, free: 77.84 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.986/5.576, allocations: 2.105 GB / 3.076 GB, free: 33.13 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003481/5.577, allocations: 105.7 kB / 3.077 GB, free: 33.03 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.8801/6.457, allocations: 66.45 MB / 3.141 GB, free: 324.1 MB / 0.948 GB