Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimaryLoadSide",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimaryLoadSide",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.764/1.764, allocations: 285.4 MB / 298 MB, free: 5.938 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001064/0.001064, allocations: 176.8 kB / 366.4 MB, free: 2.074 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.668/1.668, allocations: 205.1 MB / 0.6248 GB, free: 7.723 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008065/0.0008064, allocations: 102 kB / 0.738 GB, free: 40.25 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.45e-05/3.452e-05, allocations: 4 kB / 0.8584 GB, free: 12.97 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8325/0.8326, allocations: 115.3 MB / 0.971 GB, free: 77.81 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.349/2.182, allocations: 0.5099 GB / 1.481 GB, free: 34.64 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004287/2.183, allocations: 112.3 kB / 1.481 GB, free: 34.58 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/IntegratedPrimaryLoadSide.mo:47:3-49:73:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/BaseClasses/PartialPlant.mo:65:3-67:73:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: Modelica.Blocks.Sources.BooleanStep onChi(startTime(displayUnit = "h") = 7200) "On and off signal for the chiller" second element is: .Modelica.Blocks.Sources.BooleanStep onChi(startTime = 7200) "On and off signal for the chiller" Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide Notification: Performance of FrontEnd: time 0.1175/2.3, allocations: 55.88 MB / 1.536 GB, free: 6.555 MB / 0.8698 GB