Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.SurfaceComparison.SurfaceComparison.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.SurfaceComparison.SurfaceComparison,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_SurfaceComparison_SurfaceComparison",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.SurfaceComparison.SurfaceComparison,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_SurfaceComparison_SurfaceComparison",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.477/2.477, allocations: 387.1 MB / 399.7 MB, free: 9.457 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001765/0.001766, allocations: 176.9 kB / 492.3 MB, free: 0.6172 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.908/1.908, allocations: 221.3 MB / 0.7871 GB, free: 12.95 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001248/0.001247, allocations: 102.4 kB / 0.9267 GB, free: 14.02 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 3.174e-05/3.188e-05, allocations: 0 / 1.073 GB, free: 180.3 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.365/0.365, allocations: 142.4 MB / 1.212 GB, free: 38.43 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.515/5.88, allocations: 1.747 GB / 2.959 GB, free: 121.4 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003437/5.881, allocations: 95.94 kB / 2.96 GB, free: 121.3 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/OutputVariable.mo:39:3-71:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.SurfaceComparison.SurfaceComparison Notification: Performance of FrontEnd: time 0.08767/5.968, allocations: 37.21 MB / 2.996 GB, free: 84.1 MB / 1.151 GB