Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_RoomCapacityMultiplier",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_RoomCapacityMultiplier",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.383/2.383, allocations: 387.1 MB / 399.7 MB, free: 9.453 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001094/0.001095, allocations: 179.7 kB / 492.3 MB, free: 0.6211 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.751/1.751, allocations: 221.3 MB / 0.7871 GB, free: 12.89 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001023/0.001022, allocations: 87.95 kB / 0.9267 GB, free: 13.96 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 4.853e-05/4.854e-05, allocations: 4 kB / 1.073 GB, free: 180.3 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4204/0.4205, allocations: 142.4 MB / 1.212 GB, free: 38.43 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.314/7.735, allocations: 2.1 GB / 3.312 GB, free: 163.8 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002762/7.735, allocations: 90.77 kB / 3.312 GB, free: 163.8 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:246:11-246:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier Notification: Performance of FrontEnd: time 1.492/9.227, allocations: 185.6 MB / 3.494 GB, free: 330.5 MB / 1.151 GB