Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.529/2.529, allocations: 387.1 MB / 399.7 MB, free: 9.453 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001199/0.001199, allocations: 176.2 kB / 492.3 MB, free: 0.6172 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.927/1.927, allocations: 221.3 MB / 0.7871 GB, free: 12.91 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001236/0.001236, allocations: 95.89 kB / 0.9267 GB, free: 13.97 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 5.393e-05/5.444e-05, allocations: 0 / 1.073 GB, free: 180.3 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4541/0.4542, allocations: 142.4 MB / 1.212 GB, free: 38.38 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.574/8.028, allocations: 2.092 GB / 3.304 GB, free: 226.7 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000687/8.029, allocations: 108.6 kB / 3.304 GB, free: 226.6 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF Notification: Performance of FrontEnd: time 2.687/10.72, allocations: 0.6534 GB / 3.958 GB, free: 0.8906 MB / 1.151 GB