Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,fileNamePrefix="Buildings_9_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemporalSuperposition",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition,fileNamePrefix="Buildings_9_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_LoadAggregation_Validation_TemporalSuperposition",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.451/2.451, allocations: 387.1 MB / 399.7 MB, free: 9.477 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.002269/0.002268, allocations: 180.1 kB / 492.3 MB, free: 0.6094 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.543/1.543, allocations: 221.3 MB / 0.7871 GB, free: 12.88 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001082/0.001082, allocations: 94.58 kB / 0.9267 GB, free: 13.96 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 3.364e-05/3.366e-05, allocations: 4 kB / 1.074 GB, free: 180.2 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2874/0.2874, allocations: 142.3 MB / 1.213 GB, free: 38.37 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9395/1.227, allocations: 149.4 MB / 1.358 GB, free: 19.08 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002896/1.227, allocations: 99.58 kB / 1.359 GB, free: 19.08 MB / 0.823 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/TemporalSuperposition.mo:5:3-10:41:writable] Error: No matching function found for Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(6, {2.0, 1000000.0, 3.0, 1000000.0, 1000000.0}, {0.4, 0.0, 0.2, 1.0, 0.0}, 3) of type .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") in component candidates are .Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.temporalSuperposition(Integer i, Real(quantity = "Power", unit = "W")[i] QAgg_flow, Real(quantity = "ThermalResistance", unit = "K/W")[i] kappa, Integer curCel) => Real(quantity = "ThermodynamicTemperature", unit = "K") Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.TemporalSuperposition Notification: Performance of FrontEnd: time 0.001492/1.229, allocations: 0.5044 MB / 1.359 GB, free: 34.77 MB / 0.8386 GB