Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimaryLoadSideEconomizer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimaryLoadSideEconomizer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.311/2.311, allocations: 387.1 MB / 399.7 MB, free: 9.477 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001137/0.001137, allocations: 176.9 kB / 492.3 MB, free: 0.6211 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.627/1.627, allocations: 221.3 MB / 0.7871 GB, free: 12.9 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.000922/0.0009222, allocations: 95.14 kB / 0.9267 GB, free: 13.97 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 3.437e-05/3.481e-05, allocations: 4 kB / 1.073 GB, free: 180.3 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3366/0.3367, allocations: 142.4 MB / 1.212 GB, free: 38.41 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.573/8.91, allocations: 2.477 GB / 3.689 GB, free: 220.3 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000287/8.91, allocations: 101.6 kB / 3.689 GB, free: 220.2 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[2].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[1].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Applications/DataCenters/ChillerCooled/Examples/BaseClasses/PartialDataCenter.mo:121:5-121:17:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer Notification: Performance of FrontEnd: time 5.075/13.99, allocations: 1.131 GB / 4.82 GB, free: 162.6 MB / 1.182 GB