Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneZoneTwoDifferentOutputVariables",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.865/1.865, allocations: 289.7 MB / 302.2 MB, free: 2.156 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001772/0.001773, allocations: 184.9 kB / 371.6 MB, free: 3.379 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.183/2.183, allocations: 205.1 MB / 0.6309 GB, free: 11.8 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009828/0.0009829, allocations: 94.34 kB / 0.745 GB, free: 54.6 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 4.843e-05/4.855e-05, allocations: 4 kB / 0.8663 GB, free: 14.97 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3217/0.3218, allocations: 116.3 MB / 0.9799 GB, free: 10.52 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.783/7.104, allocations: 2.114 GB / 3.094 GB, free: 125.1 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000373/7.105, allocations: 100.6 kB / 3.094 GB, free: 125 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables Notification: Performance of FrontEnd: time 1.298/8.403, allocations: 155.2 MB / 3.245 GB, free: 223.7 MB / 0.948 GB