Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance,fileNamePrefix="Buildings_8_Buildings_ThermalZones_Detailed_BaseClasses_Examples_MixedAirHeatMassBalance",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance,fileNamePrefix="Buildings_8_Buildings_ThermalZones_Detailed_BaseClasses_Examples_MixedAirHeatMassBalance",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.77/1.77, allocations: 289.7 MB / 302.3 MB, free: 2.141 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001321/0.001322, allocations: 182.2 kB / 371.6 MB, free: 3.418 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.839/1.839, allocations: 205.1 MB / 0.6309 GB, free: 11.79 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001012/0.001012, allocations: 89.5 kB / 0.745 GB, free: 54.44 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 5.672e-05/5.675e-05, allocations: 4 kB / 0.8663 GB, free: 14.99 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3431/0.3432, allocations: 116.3 MB / 0.9799 GB, free: 10.54 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.092/7.435, allocations: 2.093 GB / 3.072 GB, free: 102.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002651/7.435, allocations: 96.92 kB / 3.073 GB, free: 102.8 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/Detailed/BaseClasses/Examples/MixedAirHeatMassBalance.mo:16:11-16:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance Notification: Performance of FrontEnd: time 1.038/8.473, allocations: 173.2 MB / 3.242 GB, free: 227.8 MB / 0.948 GB