Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC,fileNamePrefix="Buildings_8_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC,fileNamePrefix="Buildings_8_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.696/1.696, allocations: 289.7 MB / 302.2 MB, free: 2.219 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001048/0.001048, allocations: 181.1 kB / 371.6 MB, free: 3.379 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.604/1.604, allocations: 205.1 MB / 0.6309 GB, free: 11.76 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009273/0.0009271, allocations: 94.38 kB / 0.745 GB, free: 54.57 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 3.673e-05/3.696e-05, allocations: 4 kB / 0.8663 GB, free: 14.96 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2876/0.2877, allocations: 116.3 MB / 0.9799 GB, free: 10.5 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.437/7.725, allocations: 2.554 GB / 3.534 GB, free: 100.4 MB / 0.9636 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000272/7.725, allocations: 109.3 kB / 3.534 GB, free: 100.3 MB / 0.9636 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/FMI/ExportContainers/Examples/FMUs/HVACZone.mo:182:3-185:27:writable] Error: Incompatible components in connect statement: connect(souWat.ports[1], cooCoi.port_a1) - souWat.ports[1] has components {C_outflow, Xi_outflow, h_outflow, m_flow, p} - cooCoi.port_a1 has components {C_outflow, Xi_outflow, h_outflow, m_flow, p} Error: Error occurred while flattening model Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC Notification: Performance of FrontEnd: time 63.71/71.43, allocations: 13.89 GB / 17.42 GB, free: 5.336 MB / 1.229 GB