Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.171/2.171, allocations: 248.5 MB / 261.1 MB, free: 5.977 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00148/0.00148, allocations: 178.6 kB / 320.4 MB, free: 15.33 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.006/2.006, allocations: 205.2 MB / 0.571 GB, free: 11.79 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001134/0.001134, allocations: 90.47 kB / 0.6754 GB, free: 0.8789 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.793e-05/4.809e-05, allocations: 4 kB / 0.7869 GB, free: 97.79 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2326/0.2327, allocations: 106.2 MB / 0.8907 GB, free: 7.445 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.61/7.843, allocations: 2.332 GB / 3.223 GB, free: 98.48 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003873/7.843, allocations: 104.7 kB / 3.223 GB, free: 98.42 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow Notification: Performance of FrontEnd: time 1.613/9.456, allocations: 235 MB / 3.453 GB, free: 218.8 MB / 0.8855 GB