Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyExteriorWallNoWindow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.251/2.251, allocations: 248.5 MB / 261.1 MB, free: 6.047 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001559/0.001559, allocations: 174.6 kB / 320.4 MB, free: 15.36 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.978/1.978, allocations: 205.2 MB / 0.571 GB, free: 11.81 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00117/0.001169, allocations: 100.2 kB / 0.6754 GB, free: 0.8945 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.748e-05/3.788e-05, allocations: 4 kB / 0.7869 GB, free: 97.82 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2209/0.2209, allocations: 106.2 MB / 0.8907 GB, free: 7.492 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.526/7.747, allocations: 2.332 GB / 3.223 GB, free: 7.785 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003158/7.748, allocations: 101 kB / 3.223 GB, free: 7.688 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow Notification: Performance of FrontEnd: time 1.536/9.284, allocations: 235 MB / 3.452 GB, free: 125.6 MB / 0.8698 GB