Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyConstructionBoundary",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.144/2.144, allocations: 248.5 MB / 261.1 MB, free: 5.938 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001518/0.001518, allocations: 170.7 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.966/1.966, allocations: 205.2 MB / 0.571 GB, free: 11.8 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001178/0.001177, allocations: 100.2 kB / 0.6754 GB, free: 0.8906 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.425e-05/4.461e-05, allocations: 11.98 kB / 0.7869 GB, free: 97.79 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2279/0.228, allocations: 106.3 MB / 0.8907 GB, free: 7.453 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.507/7.735, allocations: 2.332 GB / 3.223 GB, free: 8.535 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000334/7.736, allocations: 103.9 kB / 3.223 GB, free: 8.434 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary Notification: Performance of FrontEnd: time 1.365/9.1, allocations: 203.1 MB / 3.421 GB, free: 158.2 MB / 0.8698 GB