Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Validation_Initialization_MixedAir",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.214/2.214, allocations: 248.5 MB / 261.1 MB, free: 6.035 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001663/0.001663, allocations: 183.3 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.999/1.999, allocations: 205.2 MB / 0.571 GB, free: 11.75 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00115/0.001149, allocations: 88.75 kB / 0.6754 GB, free: 0.8398 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.98e-05/5.006e-05, allocations: 7.984 kB / 0.7869 GB, free: 97.79 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2258/0.2259, allocations: 106.2 MB / 0.8907 GB, free: 7.441 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.456/7.682, allocations: 2.336 GB / 3.227 GB, free: 3.156 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003616/7.682, allocations: 91.95 kB / 3.227 GB, free: 3.066 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir Notification: Performance of FrontEnd: time 1.695/9.377, allocations: 284.6 MB / 3.505 GB, free: 70.4 MB / 0.8698 GB