Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_Examples_FFD_Tutorial_MixedConvection",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.199/2.199, allocations: 248.5 MB / 261.1 MB, free: 6.012 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001424/0.001423, allocations: 183.9 kB / 320.4 MB, free: 15.33 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.002/2.002, allocations: 205.1 MB / 0.571 GB, free: 11.78 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001154/0.001154, allocations: 108.4 kB / 0.6754 GB, free: 0.8594 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.909e-05/3.918e-05, allocations: 11.98 kB / 0.7869 GB, free: 97.77 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2269/0.227, allocations: 106.2 MB / 0.8907 GB, free: 7.43 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.589/7.816, allocations: 2.332 GB / 3.223 GB, free: 8.848 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003741/7.816, allocations: 99.94 kB / 3.223 GB, free: 8.75 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection Notification: Performance of FrontEnd: time 1.434/9.25, allocations: 226.9 MB / 3.445 GB, free: 130.3 MB / 0.8698 GB