Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance,fileNamePrefix="Buildings_7_0_0_Buildings_ThermalZones_Detailed_BaseClasses_Examples_MixedAirHeatMassBalance",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.182/2.182, allocations: 248.5 MB / 261.1 MB, free: 6.02 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001528/0.001528, allocations: 187.3 kB / 320.4 MB, free: 15.35 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.121/2.121, allocations: 205.2 MB / 0.571 GB, free: 11.82 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001203/0.001202, allocations: 96.31 kB / 0.6754 GB, free: 0.918 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.651e-05/3.671e-05, allocations: 4 kB / 0.7869 GB, free: 97.82 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.213/0.213, allocations: 106.2 MB / 0.8907 GB, free: 7.48 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.291/7.504, allocations: 2.209 GB / 3.1 GB, free: 139.3 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003596/7.505, allocations: 96.12 kB / 3.1 GB, free: 139.2 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/BaseClasses/Examples/MixedAirHeatMassBalance.mo:16:11-16:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance Notification: Performance of FrontEnd: time 1.246/8.751, allocations: 169.8 MB / 3.266 GB, free: 243.9 MB / 0.8698 GB