Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_Static",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.319/2.319, allocations: 248.5 MB / 261.1 MB, free: 5.969 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001493/0.001493, allocations: 184.8 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.942/1.942, allocations: 205.2 MB / 0.571 GB, free: 11.75 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.002259/0.002259, allocations: 105.3 kB / 0.6754 GB, free: 0.8359 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.718e-05/3.72e-05, allocations: 4 kB / 0.7869 GB, free: 97.8 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2109/0.211, allocations: 106.2 MB / 0.8907 GB, free: 7.461 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.913/2.124, allocations: 415.3 MB / 1.296 GB, free: 259.7 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003167/2.124, allocations: 94.41 kB / 1.296 GB, free: 259.7 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static Notification: Performance of FrontEnd: time 0.3807/2.505, allocations: 118.5 MB / 1.412 GB, free: 187.5 MB / 0.8698 GB